How to Install a Pellet Stove: Clearances, Floor Protection and Venting

Installing a pellet stove from the makers' manuals: clearances, floor protection, vent size and termination, outside air, power, permits and who should install it.

By Pellet Stove ReviewPublished 5 min readHow we research
A pellet stove being fitted with a vent pipe through a wall

Affiliate disclosure: product links on this page go to Amazon or to the maker's own store. As an Amazon Associate we earn from qualifying purchases, at no extra cost to you; links to makers' own stores earn us nothing. No retailer or brand sees our picks before they are published or has any say in them. How we choose.

A pellet stove is simpler to install than a wood stove because it can vent through a wall, but the manual still sets every distance: to the walls, to the windows outside, and under the stove. ComfortBilt's HP22 manual says installation and repair should be done by a qualified service person and that the stove should be inspected at least once a year; US Stove says its stoves should be installed by a qualified installer only and points to the National Fireplace Institute's directory of certified installers. This guide walks through what those manuals check.

Before you start

  • Put the stove in the room you use most, since a pellet stove heats the space around it first (our reading).
  • Check your local building code and whether you need a permit and an inspection; ComfortBilt's manual says installation must comply with local, regional, state and national codes.
  • Read the clearance and venting pages of your stove's own manual; the figures here are examples from specific stoves.
  • Plan the vent route first, then place the stove; ComfortBilt suggests connecting the vent to set the clearances and avoiding wall studs.

Clearances to combustibles

Example clearances from two manuals
MeasurementComfortBilt HP22US Stove US5513-W
Side wall to stove7 in8 in
Back wall to stove2 in9.25 in
Back wall to vent pipe2 in (vertical install)3 in
Rear corners to walls5 inNot shown

Combustibles include wood and drywall, ComfortBilt notes, so the distances apply to an ordinary painted wall. Use only your own stove's figures; these two differ by several inches.

Floor protection

ComfortBilt's HP22 must stand on a noncombustible floor, a floor protector or a masonry hearth, and needs Type 1 ember protection; when a clean-out tee sits inside the house, the protector must reach 2 inches beyond it. US Stove asks for a floor protector listed to UL 1618 or equivalent for Type 1 ember protection. See the hearth pad guide.

The vent

  1. Use only listed pellet vent: ComfortBilt requires 3 or 4 inch Type L or PL and says no other vent component may be used.
  2. Use 4 inch vent when the flue height is over 12 feet, when the house is above 5,000 feet, or with more than one tee or more than 180 degrees of elbows (ComfortBilt).
  3. Fit a clean-out tee; US Stove requires one so fly ash can be cleaned out, and ComfortBilt recommends one on vertical runs.
  4. Give horizontal runs a rise of 1/4 inch per foot and keep the run short with few elbows; US Stove says each elbow or tee cuts draft potential by 30 to 50%.
  5. Seal joints with high temperature silicone and screw them together, and support exterior vent with a bracket every 5 feet (ComfortBilt).

DuraVent's PelletVent instructions add that single-wall pipe must never be connected to a freestanding pellet stove. Pipe and kits are compared in the pellet vent guide.

Where the vent ends outside

  • At least 48 inches below or beside a door or window that opens, or 18 inches with outside air connected (ComfortBilt).
  • At least 12 inches below or beside a window that does not open, and 12 inches above a door or window that opens (ComfortBilt).
  • At least 12 inches out from the wall on a horizontal termination (ComfortBilt).
  • Clear of snow and anything that could block it (ComfortBilt).

ComfortBilt recommends at least 3 feet of vertical pipe when a stove vents straight through a wall, for a natural draft that helps keep smoke and odor out of the house in a power outage.

Outside air

ComfortBilt requires an outside air connection for mobile homes and recommends one in tight houses with kitchen or bath fans, or in basements, to stop negative pressure starving the stove. It must be noncombustible pipe at least 2 inches across, never PVC, ending in a downward bend outside (ComfortBilt).

Testing the draft

ComfortBilt's stove will not feed pellets unless it senses negative pressure inside with the door shut and latched, so a vent that is blocked or too long shows up as a stove that will not run (ComfortBilt; our reading).

Commissioning

US Stove's manuals end with a commissioning checklist to be completed by the person who installs the stove, covering clearances, air controls and venting, and its wood stove manual says skipping it invalidates the warranty. Keep the completed checklist with your receipt (our reading).

Mobile homes

ComfortBilt's HP22 manual cites the HUD standard, 24 CFR 3280, and adds that the stove must be bolted to the floor, take outside air and be grounded to the chassis. US Stove approves the US5513-W for mobile homes with its fresh air intake kit, per the listing.

Power and safety

Plug the stove straight into a grounded 3-prong outlet with the cord kept away from the front of the stove, and use a surge protector (ComfortBilt). ComfortBilt's manual asks for at least one smoke detector on each floor, away from the stove and close to sleeping areas, and separate carbon monoxide monitors for the areas near the stove; see the CO alarm guide.

After the install

ComfortBilt says odors and vapors come off a new stove for several days, so open windows or doors while it cures or run a pre-burn outdoors, then keep up the cleaning schedule in the cleaning guide. Choosing a stove first? See the pellet stove guide.

Frequently asked questions

Can I install a pellet stove myself?

Check your local code; ComfortBilt says installation should be done by a qualified service person, and US Stove says a qualified installer only.

How far does a pellet stove need to be from the wall?

It depends on the stove: ComfortBilt's HP22 needs 7 inches to a side wall and 2 to the back, US Stove's US5513-W 8 inches to the side and 9.25 to the back.

Does a pellet stove need a chimney?

No, it can vent through a wall with 3 or 4 inch Type L or PL pellet vent, as ComfortBilt's manual describes.

How far must the vent be from a window?

ComfortBilt says at least 48 inches below or beside a window that opens, or 18 inches with outside air connected.

Do I need a hearth pad under a pellet stove?

Yes on a combustible floor: ComfortBilt and US Stove both require a floor protector with Type 1 ember protection.

Sources

  1. HP22 pellet stove manual, ComfortBilt (SMG Hearth & Home)
  2. US5513-W owner's instruction and operation manual, United States Stove Company
  3. PelletVent installation instructions, DuraVent
  4. PelletVent installation guide, DuraVent
  5. Heating Fire Safety, U.S. Fire Administration