Skip to content
Buying guideChimney & Venting

Best Pellet Stove Vent Pipe (2026): Type L Kits, Pipe and Clean-Out Tees

Pellet stove vent compared on DuraVent's instructions and the manuals: DuraVent PelletVent kit, pipe and clean-out tee, Selkirk 3VP and ComfortBilt's kit.

By Pellet Stove ReviewPublished 6 min readHow we research
Pellet vent pipe running from a pellet stove through a wall

Affiliate disclosure: product links on this page go to Amazon or to the maker's own store. As an Amazon Associate we earn from qualifying purchases, at no extra cost to you; links to makers' own stores earn us nothing. No retailer or brand sees our picks before they are published or has any say in them. How we choose.

A pellet stove pushes its exhaust out with a blower, so it vents through sealed, listed pellet vent rather than chimney pipe: ComfortBilt's HP22 manual requires an approved 3 or 4 inch Type L or PL vent and says no other vent component may be used. DuraVent's PelletVent is listed to UL 641 as Type L low temperature venting and to UL 1777, and its instructions say single-wall pipe must never be connected to a freestanding pellet stove.

DuraVent's PelletVent 3 inch venting kit (3PVL-KHA) is our pick: a kit of the same UL 641 listed PelletVent that ComfortBilt and US Stove's manuals call for by type (per the listing; DuraVent).

Our top picks at a glance

  1. 1. Best overall

    DuraVent PelletVent 3 Inch Venting Kit (3PVL-KHA)

    Size: 3 in · Part: 3PVL-KHA kit · Listing: UL 641 Type L (DuraVent) · Use: Horizontal kit

  2. 2. Best pipe length

    Selkirk 3VP-36 3 Inch Pellet Vent Pipe

    Size: 3 in · Part: 3VP-36, 36 in · Listing: UL 641 and UL 103 (listing) · Use: Straight pipe

  3. 3. Best clean-out tee

    DuraVent PelletVent 3PVL-TR Clean-Out Tee

    Size: 3 in · Part: 3PVL-TR · Listing: PelletVent · Use: Clean-out tee

  4. 4. Best stove-matched kit

    ComfortBilt 3 Inch Pellet Stove Piping Kit

    Size: 3 in · Part: 3PVP-KCB-B · Listing: Not stated · Use: Wall kit

A 3 inch PelletVent kit for a through-the-wall install.

Size
3 in
Part
3PVL-KHA kit
Listing
UL 641 Type L (DuraVent)
Use
Horizontal kit

Pros

  • Listed Type L vent (DuraVent)
  • Parts designed to fit together (DuraVent)
  • Limited lifetime warranty on DuraVent products

Cons

  • Thin listing; check the parts list
  • 3 inch only; some runs need 4 inch

DuraVent's 3PVL-KHA is a 3 inch PelletVent kit (per the listing); DuraVent lists PelletVent to UL 641 as Type L low temperature venting and to UL 1777, and its instructions say to use only DuraVent PelletVent listed parts.

DuraVent's warranty is a limited lifetime warranty on its products when properly installed and maintained (DuraVent).

A 3 foot Type L section listed to UL 641 and UL 103.

Size
3 in
Part
3VP-36, 36 in
Listing
UL 641 and UL 103 (listing)
Use
Straight pipe

Pros

  • 304 stainless inner wall (per the listing)
  • Paintable galvanized outer wall
  • Limited lifetime warranty field

Cons

  • Mix only with Selkirk VP parts (our reading)
  • Pipe only, no fittings

Selkirk's 3VP-36 is a 3 inch by 36 inch Type L pellet vent section, listed to UL 641 and UL 103, with a 304 stainless inner wall and a paintable galvanized outer wall (per the listing).

Stay within one maker's system; DuraVent, for example, says to use only its own listed parts and not to mix them (DuraVent; our reading).

The tee that lets you clean the vent.

Size
3 in
Part
3PVL-TR
Listing
PelletVent
Use
Clean-out tee

Pros

  • US Stove requires a clean-out tee
  • Collects fly ash at the turn (US Stove)
  • Matches DuraVent PelletVent

Cons

  • Fitting only
  • Must be sealed and fastened

DuraVent's 3PVL-TR is a 3 inch PelletVent clean-out tee (per the listing); US Stove's US5513-W manual says the installation must include a clean-out tee so fly ash can be collected and the vent cleaned.

Pair it with 3PVL-12R 12 inch sections for short runs (per the listing).

ComfortBilt's 3 inch kit with adapter, tee and thimble.

Size
3 in
Part
3PVP-KCB-B
Listing
Not stated
Use
Wall kit

Pros

  • Stove adapter, clean-out tee and wall thimble (per the listing)
  • Four 12 inch pipes and swivel cap
  • Black matte finish

Cons

  • No 90 degree down-turn elbow (per the listing)
  • Cap only in galvanized

ComfortBilt's 3 inch piping kit includes a stove adapter, a clean-out tee, four 12 inch straight pipes, a 45 degree swivel cap, an exterior wall brace and a 3 inch wall thimble, but no 90 degree elbow for a down turn (per the listing).

The listing notes that the 45 degree swivel cap comes only in galvanized; stay within one system when adding parts (per the listing; our reading).

3 inch or 4 inch

ComfortBilt's HP22 manual asks for 4 inch vent when the flue height is over 12 feet or the house is above 5,000 feet, and recommends 4 inch with more than one tee or more than 180 degrees of elbows; its HP22i insert manual sets the switch at 18 feet of vent or liner. US Stove's US5513-W accepts 3 or 4 inch vent, per its manual. Use an increaser to step from the stove's 3 inch collar to 4 inch pipe (DuraVent; our reading).

Routing rules

  • Every elbow or tee cuts draft potential by 30 to 50%, so keep the run short (US Stove).
  • Horizontal runs rise 1/4 inch per foot (ComfortBilt).
  • Seal joints with high temperature silicone and fasten them with screws (ComfortBilt).
  • Support exterior vent with a bracket every 5 feet (ComfortBilt).
  • At least 3 feet of vertical pipe on a through-the-wall install, for natural draft in an outage (ComfortBilt).
  • Never connect pellet vent to a vent serving another appliance, and never fit a flue damper (ComfortBilt HP22i).

Planning the run

DuraVent's install guide starts with the stove maker's limits: maximum horizontal run, minimum and maximum vertical rise and maximum offset, which differ from stove to stove. It then has you pick the termination, horizontal through a wall or vertical through the roof, and count the parts the route needs (DuraVent).

  1. Fit an appliance adapter to the stove's exhaust and seal it with high temperature sealant (DuraVent).
  2. Add a clean-out tee at the first turn (US Stove; DuraVent).
  3. Run pipe at a slight rise to the wall thimble or ceiling support (ComfortBilt; DuraVent).
  4. Rise at least 3 feet outside a through-the-wall run before the cap, where the stove maker recommends it (ComfortBilt).
  5. Fit the cap, brackets and storm collar, and check every clearance (DuraVent).

Through walls, floors and attics

DuraVent's instructions use a wall thimble through walls, a ceiling support or firestop spacer through each floor and ceiling, and an attic insulation shield so insulation stays clear of the vent; it says never to fill a clearance space with insulation. Clearances to combustibles come from the vent's own listing and the stove's manual (DuraVent; ComfortBilt).

Vertical runs

A vertical run through the roof needs a ceiling support or firestop spacer at each floor and ceiling, an attic insulation shield, and flashing with a storm collar and cap at the roof, DuraVent's guide shows. A vertical run also gives the stove some natural draft when the power fails, which ComfortBilt counts in its favor (DuraVent; ComfortBilt).

Sealing and fastening

ComfortBilt's insert manual asks for every pellet vent joint to be sealed with high temperature RTV silicone and screwed together, and DuraVent seals its appliance adapter with high temperature sealant. Pellet stoves push exhaust under pressure, so a leaking joint can let fumes and fine ash into the house; recheck the joints each season (ComfortBilt; our reading).

Termination outside

The vent must end outside, at least 12 inches out from the wall on a horizontal run, and 48 inches below or beside an opening door or window, or 18 inches with outside air (ComfortBilt). See the installation guide.

Pellet vent in a chimney

PelletVent is also listed as a masonry reliner, in which case DuraVent gives 0 inches of clearance from the vent to the masonry. For inserts, see the chimney liner guide.

Outside air

Many pellet installs pair the vent with an outside air pipe; ComfortBilt requires one in mobile homes and asks for noncombustible pipe at least 2 inches across, never PVC, ending in a downward bend outside.

Kits or parts

A kit, such as DuraVent's 3PVL-KHA or ComfortBilt's 3 inch kit, gathers the common parts for a through-the-wall install; buying parts separately suits a vertical run or a longer route (per the listings; our reading). Either way, check the parts against the route before ordering; ComfortBilt's kit has no 90 degree elbow for a down turn, its listing says, so a stove with a downward exit or a low wall exit needs one added to the order.

Cleaning

US Stove says 90 degree elbows collect fly ash and soot, and that the vent should be inspected each year or each ton of pellets. A 3 inch brush on a flexible handle reaches through the clean-out tee; see the cleaning guide.

DuraVent PelletVent 3 Inch Venting Kit (3PVL-KHA)Check price on Amazon

Frequently asked questions

What vent pipe does a pellet stove need?

Listed 3 or 4 inch Type L or PL pellet vent; ComfortBilt says no other vent component may be used.

Can I use regular stove pipe on a pellet stove?

No: DuraVent says single-wall pipe must never be connected to a freestanding pellet stove.

When do I need 4 inch pellet vent?

ComfortBilt's HP22 manual says when the flue rises over 12 feet, above 5,000 feet altitude, or with more than one tee or 180 degrees of elbows.

Does pellet vent need a clean-out tee?

US Stove requires one so fly ash can be collected and the vent cleaned.

How far must pellet vent end from a window?

ComfortBilt says 48 inches below or beside a window that opens, or 18 inches with outside air.

Sources

  1. PelletVent installation instructions, DuraVent
  2. PelletVent installation guide, DuraVent
  3. HP22 pellet stove manual, ComfortBilt (SMG Hearth & Home)
  4. HP22i pellet stove insert manual, ComfortBilt
  5. US5513-W owner's instruction and operation manual, United States Stove Company

Share this article

Chimney & VentingPellet VentPellet StovesBest PicksVenting