Affiliate disclosure: product links on this page go to Amazon or to the maker's own store. As an Amazon Associate we earn from qualifying purchases, at no extra cost to you; links to makers' own stores earn us nothing. No retailer or brand sees our picks before they are published or has any say in them. How we choose.
Most wood stove fires start with an installation problem: too little clearance, a missing floor protector or a connector run through a wall or ceiling the wrong way. US Stove's manuals say its stoves should be installed by a qualified installer only and point to the National Fireplace Institute's directory. This guide walks through what those manuals check, so you know what a good install looks like.
Before you start
- Check your local building code and permit rules; US Stove's manuals require installation to comply with local codes (our reading).
- Have an existing chimney inspected before use; US Stove's commissioning checklist asks for the date of the inspection.
- Choose the spot: US Stove says never to install a stove in a hallway or near a staircase, where it could block the way out in a fire.
What the install needs
- The stove, its legs or pedestal and the tools to fit the flue collar; US Stove's manual names a 1/2 inch socket or wrench (US Stove).
- A noncombustible floor protector of the size the manual gives (US Stove).
- Every chimney and connector part the installation needs (US Stove).
- An outside air kit if the house is tight or a mobile home (US Stove).
Floor protection
On a combustible floor the stove needs a noncombustible floor protector for ember protection, UL listed or equal, US Stove says. For the US1100E it must reach 16 inches in front (18 in Canada), 8 inches to each side and 2 inches behind, and run under any horizontal flue pipe with 2 inches to spare on each side.
Hearth pads and stove boards are compared in the hearth pad guide.
Clearances
Every stove has its own clearances to walls and furniture, set out in a diagram in its manual; US Stove says they must be strictly followed. Two rules from US Stove's US1100E manual apply to any stove: nothing combustible within 4 feet of the front, and no wood stored on the floor protector, under the pipe or within the clearances.
The U.S. Fire Administration adds a household rule: keep anything that can burn at least 3 feet from wood stoves and fireplaces.
The connector
- Use the diameter of the stove's flue collar; US Stove's stoves take 6 inch black or blued steel pipe, and its wall pass-through instructions name a minimum 24 gauge single wall steel connector.
- Keep it short with few elbows; US Stove says two 90 degree elbows cool the gases and build creosote.
- Never run the connector through an attic, roof space, closet, concealed space, floor or ceiling (US Stove).
- Through a wall, use a listed wall pass-through with the spacing the manual gives (US Stove).
See the stove pipe guide.
The chimney
US Stove's manuals set a minimum chimney height of 12 feet, ask that the flue be the same inside diameter as the stove's exhaust, and note that a flue too small causes draft problems. An inside chimney stays warmer, drafts better and builds less creosote than an outside one, US Stove adds. A barometric draft stabilizer is prohibited on its stoves.
An old masonry chimney may need a liner; see the chimney liner guide.
Draft
The chimney, not the stove, makes the draft, US Stove says, and the amount depends on the chimney's length, local geography and nearby obstructions. Too much draft can overheat the stove, and too little lets smoke roll out when the door opens (US Stove).
Air for the fire
A stove needs a supply of air. US Stove sells an outside air kit that its manuals require in mobile homes and in tight houses or houses with negative pressure, where a stove draws badly or smoke rolls out. Never connect a wood stove to a hot air duct or distribution system (US Stove).
Mobile homes
Only stoves approved for mobile homes can go in one; US Stove approves the US1100E and TH-100 with their outside air kits, and its manuals have a section on the extra steps.
Check your work
Before the very first fire, go back through the manual's commissioning checklist: hearth pad, clearances, connector, chimney and air controls; US Stove says skipping it invalidates the warranty. Keep a copy with the receipt and the manual.
Before the first fire
New stove paint cures on the first few fires; US Stove asks for a series of low to medium burns and says to keep the single-wall pipe temperature below 475 degrees on a magnetic thermometer about 18 inches above the stove. See the thermometer guide.
Hot surfaces and fire safety
US Stove's manuals warn that the stove is hot while operating and to keep children, clothing and furniture away, since contact may burn skin. Keep a fire extinguisher handy, the EPA says, and keep flammable liquids well away from the stove while it is in use (US Stove).
Alarms and inspection
Fit smoke alarms and carbon monoxide alarms; the CPSC says CO alarms on every level and outside sleeping areas. See the CO alarm guide. The U.S. Fire Administration says to have heating equipment and chimneys cleaned and inspected every year by a professional.
If there is a chimney fire
US Stove's manual says to push the air control fully closed to starve the fire of oxygen and call the fire department. Regular sweeping prevents it; see the chimney sweep kit guide and the wood stove guide.
Frequently asked questions
Can I install a wood stove myself?
Check your local code and permit rules; US Stove says its stoves should be installed by a qualified installer only.
How far does a wood stove need to be from the wall?
Use the clearance diagram in your stove's manual; US Stove also says nothing combustible within 4 feet of the US1100E's front.
How big a hearth pad does a wood stove need?
For US Stove's US1100E: 16 inches in front (18 in Canada), 8 to each side and 2 behind, UL listed or equal.
How tall does a wood stove chimney need to be?
US Stove's manuals give a 12 foot minimum for the US1100E and TH-100.
Can stove pipe go through a ceiling?
Not the single-wall connector: US Stove says it must never pass through an attic, closet, concealed space, floor or ceiling; use listed chimney parts.
How often should a chimney be inspected?
Every year by a professional, says the U.S. Fire Administration.
Sources
- US1100E (Defender II) owner's instruction and operation manual, United States Stove Company
- TH-100 owner's instruction and operation manual, United States Stove Company
- Heating Fire Safety, U.S. Fire Administration
- Carbon Monoxide Information Center, U.S. Consumer Product Safety Commission
- Best Wood-Burning Practices (Burn Wise), U.S. Environmental Protection Agency
Related guides
Best Fireplace Inserts (2026): Pellet, Wood and Electric Compared
The ComfortBilt HP22i is our pick: a pellet insert with 1.542 grams an hour and up to 41,810 BTU in its manual, vented through a stainless liner in a masonry fireplace.
Best Wood Stoves (2026): EPA-Certified Stoves From the Manuals
The US Stove US1100E is our pick: its manual gives 15,196 to 40,594 BTU an hour from an 18 inch log firebox, and the EPA list shows its line certified to the 2020 rules.
Catalytic vs Non-Catalytic Wood Stoves: How They Burn and Which to Choose
Both meet the same EPA limit. A catalytic stove burns smoke in a coated honeycomb for a long, even heat; a non-catalytic one uses a baffle and hot air and is simpler to run.